Vulnerabilities in the CA certificate download and the diagnostic log functionality on B/W small multifunction and single-function printers - Konica Minolta

Vulnerabilities in the CA certificate download and the diagnostic log functionality on B/W small multifunction and single-function printers

January 29, 2026

Konica Minolta, Inc.

Dear Customers,

We deeply appreciate your constant patronage to Konica Minolta products.

Two security vulnerabilities have been newly identified in the indicated models.

This advisory provides an overview of the issue and guidance on how to resolve them.

Please note that, at the time of publication, there have been no confirmed security incidents globally resulting from the exploitation of these vulnerabilities.

Overview of the vulnerabilities

CVE-IDCVSS AssessmentBase ScoreVulnerabilities description
CVE-2025-53869CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N6.3The set of root certificates used by the product may be replaced with a set of arbitrary certificates by a man-in-the-middle attack. (CWE-295: Improper certificate validation)
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N3.7
CVE-2025-55704CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N6.9An attacker may obtain the logs of the affected product and obtain sensitive information within the logs. (CWE-912: Hidden Functionality)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N5.3

Affected Models

Product nameProgram nameAffected versionFixed version
bizhub 5021iFirmware1.021.04
bizhub 5001iFirmware1.031.05
bizhub 4221iFirmware1.021.04
bizhub 4201iFirmware1.021.04
bizhub 5020iMain-FirmwareU2412241059 (Ver S)or earlierU2505151336 (Ver T) or later
Sub-Firmware1.15 or earlier1.16 or later
bizhub 5000iMain-Firmware1.33 or earlier1.34 or later
Sub-Firmware1.15 or earlier1.16 or later
bizhub 4020iMain-FirmwareU2412241059 (Ver S)or earlierU2505151336 (Ver T) or later
Sub-Firmware1.15 or earlier1.16 or later
bizhub 4000iMain-Firmware1.29 or earlier1.30 or later
Sub-Firmware1.15 or earlier1.16 or later

Remediation

Download the Firmware Update Tool from Drivers & Downloads and upgrade the firmware of your device.

General Security Recommendations

To ensure a secure operating posture for your multifunction devices, and to reduce exposure to the vulnerability described in this advisory, Konica Minolta strongly recommends applying the following configuration best practices:

  1. Avoid Direct Internet Exposure

Place devices behind firewalls and use private IP addressing.

  • Change Default Passwords

Change default credentials and implement strong passwords for administrative and network functions.

  • Use Strong Passwords for Services

Ensure strong credentials are configured for SMTP, LDAP, SMB, WebDAV, and any other integrated services.

  • Disable Unused Services

Turn off unused ports or protocols to reduce attack surface.

  • Use Secure Protocols

Configure devices to use encrypted communications (e.g., HTTPS, LDAPS, IPPS) where supported.

  • Monitor Device Activity

Regularly review device logs and network traffic for suspicious behaviour.

  • Enable Authentication Where Available

Use built-in user authentication features to prevent unauthorised access to device functions.

For comprehensive information on secure configuration, please refer to our Product Security web site.

Enhancing the Security of Products and Services

Konica Minolta considers the security of its products and services to be an important responsibility and will continue to actively respond to incidents and vulnerabilities.

Related Information

JVNVU#92878805

Contact